问题现象

客户现场12508-S设备,双主控。当设备重启后,主框与备框上都是5槽位的主控板active灯闪烁,堆叠master是主框的5槽位的主控。理论上,应该小槽位的主控成为主用主控板。

Slot   Type                 State    Subslot  Soft Ver             Patch Ver

2/0    LSXM1TGS16SF3        Normal   0        S12500S-7180         None     

2/1    LSXM1TGS16SF3        Normal   0        S12500S-7180         None     

2/2    LSXM1GP24TSSE3       Normal   0        S12500S-7180         None     

2/3    LSXM1GP24TSSE3       Normal   0        S12500S-7180         None     

2/4    LSXM1SUPD3           Standby  0        S12500S-7180         None     

2/5    LSXM1SUPD3           Master   0        S12500S-7180         None     

2/6    NONE                 Absent   0        NONE                 None     

2/7    NONE                 Absent   0        NONE                 None     

2/8    LSXM1GT48SE3         Normal   0        S12500S-7180         None     

2/9    LSXM1GT48SE3         Normal   0        S12500S-7180         None     

2/10   LSXM1FAB08D3         Normal   0        S12500S-7180         None      

2/11   LSXM1FAB08D3         Normal   0        S12500S-7180         None     

2/12   LSXM1FAB08D3         Normal   0        S12500S-7180         None     

2/13   NONE                 Absent   0        NONE                 None   

告警信息

1、检查FLASH上的文件占用情况,4号槽位只剩51M的空间,而5号槽位还剩271M

2、主控板上的flash类型为NORflash,为JFFS2文件系统,该文件系统的技术特点决定了flash内的文件愈多,挂载文件系统和查找主机软件的时间会越长,系统的启动时间就会越长,文件系统本身决定的。

34号槽位由于文件数目和文件大小过多,软件加载就会变慢,而5号槽位加载会更快;系统起来默认的是按照小槽位为主用主控,如果大槽位先起来,逻辑上会等15秒的时间,如果小槽位还不起来,那么5号槽位就升为主了;现网5号槽位起来的时间要比4号槽位早了15秒以上;

 

Directory of chassis2#slot4#flash:

   0 -rw-   219920384 May 20 2016 11:27:12   S12500S-CMW710-R7180.ipe

   1 -rw-     1266327 Jun 03 2016 21:42:10   diag_GRZHJF-12508-IRF_20160603-213751.tar.gz

   2 drw-           - Mar 22 2016 03:39:17   diagfile

   3 -rw-         735 Jun 03 2016 23:45:14   hostkey

   4 -rw-        6546 Jun 03 2016 23:16:04   ifindex.dat

   5 -rw-           0 Jun 02 2016 18:33:17   lauth.dat

   6 drw-           - May 19 2016 12:01:26   license

   7 drw-           - Apr 19 2016 17:59:19   logfile

   8 -rw-    27195392 Mar 17 2016 18:44:38   s12500s-cmw710-boot-r7179.bin

   9 -rw-   192417792 Mar 17 2016 18:53:58   s12500s-cmw710-system-r7179.bin

  10 drw-           - Mar 22 2016 03:39:17   seclog

  11 -rw-         591 Jun 03 2016 23:45:14   serverkey

  12 -rw-       22887 Jun 03 2016 23:16:06   startup.cfg

  13 -rw-     1144624 Jun 03 2016 23:16:44   startup.mdb

  14 drw-           - May 20 2016 12:09:49   versionInfo

  15 -rwh          20 Jun 03 2016 23:15:44   .snmpboots

  16 drwh           - Mar 21 2016 17:11:09   .trash

503808 KB total (51472 KB free)

 

Directory of flash:

   0 -rw-    27390976 May 20 2016 11:44:15   S12500S-CMW710-BOOT-R7180.bin

   1 -rw-   192522240 May 20 2016 11:59:22   S12500S-CMW710-SYSTEM-R7180.bin

   2 -rw-           0 Jun 03 2016 23:47:48   diag_GRZHJF-12508-IRF_20160603-234747.gz

   3 drw-           - Mar 22 2016 06:31:04   diagfile

   4 -rw-         735 Jun 03 2016 21:59:30   hostkey

   5 -rw-        6546 Jun 03 2016 23:16:04   ifindex.dat

   6 -rw-           0 Jun 02 2016 18:32:59   lauth.dat

   7 drw-           - May 19 2016 12:02:42   license

   8 drw-           - May 19 2016 12:02:42   logfile

   9 drw-           - Mar 22 2016 06:31:04   seclog

  10 -rw-         591 Jun 03 2016 21:59:30   serverkey

  11 -rw-       22887 Jun 03 2016 23:16:06   startup.cfg

  12 -rw-     1144624 Jun 03 2016 23:16:09   startup.mdb

  13 drw-           - May 20 2016 12:09:20   versionInfo

  14 -rwh          20 Jun 03 2016 23:15:44   .snmpboots

  15 drwh           - Mar 21 2016 17:07:06   .trash

503808 KB total (271612 KB free)

解决办法

4号槽位删除不相关的文件,保证剩余空间要比5好槽位多;

案例信息

案例类型:经验案例
案例号:201606080008
创建时间:2016年6月8日
更新时间:2016年10月11日
发布时间:2016/6/8 13:02:28
文章密级:游客可见
有效期:长期有效
发布者:程飞 [c10212]
点击次数:1459
评论平均得分:0
关键词:S12508-S,双主控,大槽位主控板,主用主控板
产品线:园区高端交换机产品线
产品系列:S12500系列
产品版本:
故障类型:

常用操作
收藏